RESULTS OF USING SINGLE-USE FLEXIBLE BRONCHOSCOPE FOR CRITICAL AND EMERGENCY PATIENTS
Main Article Content
Abstract
Objective: Describe results of bronchoscopy with single-use flexible bronchoscope and difficulties, complications of this procedure. Method: Descriptive study on 34 critical patients, who received bronchoscopy with single-use flexible bronchoscope. Results: Average age was 63 ± 19, 64,7% were 60 and over. 85,3% of these patients were males. The most common day of procedure was day 4. The average time to perform bronchoscopy was 10,7 ± 3,5 minutes, from 6 to 20 minutes. About route of entry for bronchoscopy, orotracheal tube were majority (79%). 94% procedures were able for performers reach all lung segments, 62%, 18% procedures were disrupted. About general satisfaction with the bronchoscopy, 21% were more satisfied, 50% were equal and 29% were unsatisfied compare with conventional bronchoscopy. Conclusion: Bronchoscopy with a single-use bronchoscope is a safe and effective method equivalent to conventional bronchoscopy, easily implemented in critical care units with limited facilities and human resources.
Article Details
Keywords
flexible bronchoscopy, single-use flexible bronchoscope
References
2. Chang SH, Jiang J, Kon ZN, et al. Safety and Efficacy of Bronchoscopy in Critically Ill Patients With Coronavirus Disease 2019. Chest. 2021; 159(2):870-872.
3. Deasy KF, Sweeney AM, Danish H, O’Reilly E, Ibrahim H, Kennedy MP. Single Use or Disposable Flexible Bronchoscopes: Bench Top and Preclinical Comparison of Currently Available Devices. J Intensive Care Med. 2023;38(6):519-528.
4. Flandes J, Giraldo-Cadavid LF, Alfayate J, et al. Bronchoscopist’s perception of the quality of the single-use bronchoscope (Ambu aScope4TM) in selected bronchoscopies: a multicenter study in 21 Spanish pulmonology services. Respir Res. 2020;21(1):320.
5. Marshall DC, Dagaonkar RS, Yeow C, et al. Experience With the Use of Single-Use Disposable Bronchoscope in the ICU in a Tertiary Referral Center of Singapore. Journal of Bronchology & Interventional Pulmonology. 2017;24(2):136-143.
6. Rutala WA, Weber DJ. Reprocessing endoscopes: United States perspective. Journal of Hospital Infection. 2004;56:27-39.
7. Srinivasan A, Wolfenden LL, Song X, et al. An Outbreak of Pseudomonas aeruginosa Infections Associated with Flexible Bronchoscopes. N Engl J Med. 2003;348(3):221-227.
8. Wahidi MM, Lamb C, Murgu S, et al. American Association for Bronchology and Interventional Pulmonology (AABIP) Statement on the Use of Bronchoscopy and Respiratory Specimen Collection in Patients With Suspected or Confirmed COVID-19 Infection. Journal of Bronchology & Interventional Pulmonology. 2020;27(4): e52-e54.