RESULTS SURGERY WITH LOCKING PLATE FOR TREATMENT OF DISTAL RADIUS FRACTURES AT CENTRAL MILITARY HOSPITAL 108
Main Article Content
Abstract
Objective: Evaluate the results of surgical treatment with locking plate for closed fractures of the distal radius at the 108 Military Central Hospital. Subjects and methods: Describe 39 patients diagnosed with closed fractures of the distal radius who underwent surgical treatment with locking plate at the Department of Upper Extremity Trauma and Microsurgery - 108 Military Central Hospital from January 2020 to December 2023. Results: There were 21 males (53.8%) and 18 females (46.2%). The average age was 50.9 (ranging from 24 to 82 years old), with the highest rate of >60 years old being 36%. The overall results were very good at 64.1%, good at 25.6% and fair at 10.3%. Conclusion: The treatment of closed distal radius fractures by open reduction surgery and bone fixation with locking plate has shown positive recovery results.
Article Details
References
2. Thompson, P. W., Taylor, J. & Dawson, A. J. I. The annual incidence and seasonal variation of fractures of the distal radius in men and women over 25 years in Dorset, UK. 35, 462-466 (2004).
3. Kannus, P. et al. Nationwide decline in incidence of hip fracture. Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research 21, 1836-1838, doi:10.1359/jbmr.060815 (2006).
4. Brogren, E., Petranek, M. & Atroshi, I. Incidence and characteristics of distal radius fractures in a southern Swedish region. BMC musculoskeletal disorders 8, 48, doi:10.1186/ 1471-2474-8-48 (2007).
5. O'Neill, T. W. et al. Incidence of distal forearm fracture in British men and women. Osteoporosis international: a journal established as result of cooperation between the European Foundation for Osteoporosis and the National Osteoporosis Foundation of the USA 12, 555-558, doi:10.1007/ s001980170076 (2001).
6. Rein, S., Schikore, H., Schneiders, W., Amlang, M. & Zwipp, H. Results of dorsal or volar plate fixation of AO type C3 distal radius fractures: a retrospective study. J Hand Surg Am 32, 954-961, doi:10.1016/j.jhsa.2007.05.008 (2007).
7. Rozental, T. D. & Blazar, P. E. Functional outcome and complications after volar plating for dorsally displaced, unstable fractures of the distal radius. J Hand Surg Am 31, 359-365, doi:10.1016/j.jhsa.2005.10.010 (2006).
8. Earp, B. E., Foster, B. & Blazar, P. E. The use of a single volar locking plate for AO C3-type distal radius fractures. Hand (N Y) 10, 649-653, doi:10.1007/s11552-015-9757-8 (2015).