ANATOMICAL VARIATIONS OF THE CIRCLE OF WILLIS ON 128-SLICE COMPUTED TOMOGRAPHY ANGIOGRAPHY IN PATIENTS WITH RUPTURED CEREBRAL ANEURYSMS
Main Article Content
Abstract
Objective: To describe the anatomical variations of the Circle of Willis on 128-slice computed tomography angiography in patients with ruptured cerebral aneurysms.
Methods: A cross-sectional descriptive study with retrospective and prospective patient enrollment was conducted in 69 patients with ruptured cerebral aneurysms who underwent cerebral computed tomography angiography at Thai Nguyen National Hospital from January 2022 to June 2026. Data were analyzed using SPSS version 25.0.
Results: The most common variation in the anterior circulation was A1 segment hypoplasia of the anterior cerebral artery (9.4%), while the most common variation in the posterior circulation was absence of the posterior communicating artery (74.2%). Type A was the most common configuration in the anterior circulation (65.2%), whereas type E was the most common configuration in the posterior circulation (53.6%). A complete Circle of Willis was observed in 14.5% of patients. No statistically significant association was found between Circle of Willis anatomical variations and age group.
Conclusion: A complete Circle of Willis was uncommon in patients with ruptured cerebral aneurysms, with anatomical variations observed in both the anterior and posterior circulations.
Keywords
Anatomical variations of the Circle of Willis, computed tomography angiography, cerebral aneurysm
Article Details
References
2. Saha A, Bhattacharya A, Mullick A. Morphological evaluation of completeness of Circle of Willis. Anat Sci Int. 2026;101(1):54-60.
3. Zimelewicz Oberman D, Perez Akly MS, Rabelo NN, et al. Morphologic variations in the Circle of Willis as a risk factor for aneurysm rupture in the anterior and posterior communicating arteries. World Neurosurg. 2021;154:e155-e162.
4. Trandafilović M, Milić M, Antović A, et al. Hypoplastic arteries of the cerebral arterial ring in the blind spot of computed tomography angiography. Folia Morphol (Warsz). 2024;83(3):589-596.
5. Krabbe-Hartkamp MJ, van der Grond J, de Leeuw FE, et al. Circle of Willis: morphologic variation on three-dimensional time-of-flight MR angiograms. Radiology. 1998;207(1):103-111.
6. Phạm Thu Hà. Nghiên cứu giải phẫu đa giác Willis của các bệnh nhân phình động mạch não trên máy chụp cắt lớp vi tính 128 dãy tại Bệnh viện Bạch Mai Luận văn chuyên khoa cấp II, Trường Đại học Y Hà Nội; 2018.
7. Nguyễn Duy Toàn, Vũ Văn Sơn, Lành Mỹ Duyên và cộng sự. Đặc điểm biến thể giải phẫu đa giác Willis trên cắt lớp vi tính 64 dãy ở bệnh nhân có và không có đột quỵ não. Tạp chí Y dược học Quân sự 49 (2024).
8. Machasio RM, Nyabanda R, Mutala TM. Proportion of variant anatomy of the Circle of Willis and association with vascular anomalies on cerebral CT angiography. Radiol Res Pract. 2019;2019:6380801.