CURRENT OF INJURY PREDICTS EARLY OUTCOME OF THRESHOLD IN IMPLANTING PERMANENT CARDIAC PACEMAKER

Phạm Hồng Phương1, Phan Việt Tâm Anh1, Nguyễn Hữu Long1,
1 Nghe An Friendship General Hospital

Main Article Content

Abstract

Objectives: The aim of this sudy was to evaluate the role ofcurrent of injury which predicts the early outcome in performance of implanting permanent cardiac pacemaker device. Subjects and method: 91 patients with permanent cardiac pacemaker. A total 127 active-fixation leads were studied and 108 leads had a current of injury. Results: Ninety-one ventricular leads were implanted successfully, and 77 leads had a COI. From baseline to the time of fixation, the duration of the intracardiac EGM in ventricular leads increased from 96,8 ± 18,2 ms to 168,5 ± 31,8 ms (p < 0,01), and the ST-segment elevation increased from 64,1 ± 9,5 ms to 111,2 ± 15,1 ms, pacing threshold at the time of fixation decreased from 0,78 ± 0,15 V to 0,51 ± 0,07 V at 10 minutes after fixation. Thirty-six atrial leads were implanted successfully and thirty-one leads had a COI. The duration of intracardiac EGM in atrial leads increased from 64,1 ± 9,5 ms at baseline to 111,2 ± 15,1 ms at the time of fixation, the ST-segment elevation 0,85 ± 0,41 mV to 2,43 ± 0,73 mV at the same times, pacing threshold reduced from 0,9 ± 0,17 V at the time of fixation to 0,65 ± 0,18 V at 10 minutes after fixation. Conclusion: The leads present the COI, within 10 minutes, pacing threshold will return to an acceptable range even if the initial threshold is high.

Article Details

References

1. Deo, R. and C.M. Albert, Epidemiology and genetics of sudden cardiac death. Circulation, 2012. 125(4): p. 620-637.
2. Trần Đỗ Trinh, Đ.t.K.C., Hàn Thành Long, Điều trị loạn nhịp tim bằng tạo nhịp. 1983, Nhà xuất bản y học - Hà Nội - Việt Nam.
3. Thống, T., Kĩ thuật máy tạo nhịp. 1998, Tài liệu tham khảo - Công ty Medtronik Việt Nam. 18 trang.
4. Saxonhouse, S.J., J.B. Conti, and A.B.J.J.o.t.A.c.o.C. Curtis, Current of injury predicts adequate active lead fixation in permanent pacemaker/defibrillation leads. 2005. 45(3): p. 412-417.
5. Shali, S., et al., Time course of current of injury is related to acute stability of active-fixation pacing leads in rabbits. PloS one, 2013. 8(3): p. e57727.
6. Haghjoo, M., et al., Prediction of midterm performance of active‐fixation leads using current of injury. 2014. 37(2): p. 231-236.
7. Kusumoto, F.M., et al., 2018 ACC/AHA/HRS guideline on the evaluation and management of patients with bradycardia and cardiac conduction delay: executive summary: a report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines, and the Heart Rhythm Society. Journal of the American College of Cardiology, 2019. 74(7): p. 932-987.
8. Bộ Y Tế, Hướng dẫn quy trình kĩ thuật nội khoa, chuyên ngành tim mạch. Ngày 03 tháng 10 năm 2014: Quyết định số: 3983/QĐ-BYT.