AESTHETIC RESULTS AND PATIENT SATISFACTION USING 3D PRINTED RESIN TEMPORARY CROWN

Thanh Tùng Khiếu1,, Thị Quỳnh Hương Chu 2, Phú Hoà Nguyễn1, Thu Hương Nguyễn1
1 Hanoi Medical University
2 Hanoi Central Odonto-Stomatology Hospital

Main Article Content

Abstract

Objectives: Aesthetic results and patient satisfaction using 3D printed bio-resin temporary restorations in the anterior teeth. Material and methods: Descriptive study in 32 anterior teeth was placed printed bio-resin temporary crowns at the School of Odonto-Stomatology - Hanoi Medical University in 2021 - 2022. Teeth were prepared, scanned, designed and 3D printed using DIO Navi C&B resin. The temporary crown was cemented and evaluated the aesthetic results and the patient's satisfaction at the time immediately after cementation and 7 days after cementation. Results: 32 anterior teeth using 3D printed resin temporary crown achieved very good results in terms of shape, immediately after cementation (87.50%) and at 7 days after cementation (81.25%). The temporary crown color achieved good and very good results over 90% at both times after cementation and 7 days after cementation. Surface gloss achieved good results at 87.5% at the time after cementation and good results at 62.5% at 7 days after cementation. 100% of patients are satisfied and very satisfied with the treatment results. Conclusion: 3D printed resin temporary crown ensure the aesthetic factor and satisfy the patient about the treatment results while waiting for the permanent crowns.

Article Details

References

1. Burns DR, Beck DA, Nelson SK, Committee on Research in Fixed Prosthodontics of the Academy of Fixed P. A review of selected dental literature on contemporary provisional fixed prosthodontic treatment: report of the Committee on Research in Fixed Prosthodontics of the Academy of Fixed Prosthodontics. J Prosthet Dent. 2003;90(5):474-497.
2. Lodding DW. Long-term esthetic provisional restorations in dentistry. Curr Opin Cosmet Dent. 1997;4:16-21.
3. Balkenhol M, Knapp M, Ferger P, Heun U, Wostmann B. Correlation between polymerization shrinkage and marginal fit of temporary crowns. Dent Mater. 2008; 24(11):1575-1584.
4. Lee WS, Lee DH, Lee KB. Evaluation of internal fit of interim crown fabricated with CAD/CAM milling and 3D printing system. J Adv Prosthodont. 2017;9(4):265-270.
5. Hickel R PA, Tyas M, et al. FDI World Dental Federation - clinical criteria for the evaluation of direct and indirect restorations. Update and clinical examples. J Adhes Dent 2010;12(4):259-272.
6. Al-Halabi MN, Bshara N, Nassar JA, Comisi JC, Rizk CK. Clinical Performance of Two Types of Primary Molar Indirect Crowns Fabricated by 3D Printer and CAD/CAM for Rehabilitation of Large Carious Primary Molars. Eur J Dent. 2021.
7. Hà Huy Hoàng, “Kết quả phục hình tạm ở bệnh nhân mất răng nhóm răng trước bằng composite gia cố sợi.” Luận văn bác sỹ Nội trú, Trường Đại học Y Hà Nội. 2019
8. Sulaya K, Guttal SS. Clinical evaluation of performance of single unit polyetheretherketone crown restoration-a pilot study. J Indian Prosthodont Soc. 2020;20(1):38-44.