RESEARCH ON SIZE AND COLLAPSE INDEX VARIATION OF THE INFERIOR VENA CAVA BEFORE AND AFTER DIALYSIS BY ULTRASOUND IN PATIENTS WITH END-STAGE CHRONIC KIDNEY DISEASE ON HEMODIALYSIS
Main Article Content
Abstract
Objective: Evaluate size and collapse index variation of the inferior vena cava before and after dialysis by 2D ultrasound before and after dialysis in patients with end-stage chronic kidney disease on hemodialysis. Subjects and methods: Cross-sectional descriptive study in 70 chronic kidney disease patients on dialysis from January 2022 to June 2023. Measure the size of the inferior vena cava by ultrasound at the time before and after dialysis. Results: Results: Patients with end-stage chronic kidney disease on dialysis had the size of the inferior vena cava on ultrasound clearly reduced after dialysis: Dmax IVCe decreased from 1.8 ± 0.409 (cm) to 1.6 ± 0.365 (cm) (p<0.01), Dmax IVCi decreased from 1 ± 0.409 (cm) to 0.75 ± 0.32 (cm) (p <0.01); The IVC-CI inferior vena cava collapse index increased significantly after dialysis: from 0.42 ± 0.116 to 0.497 ± 0.134 (p<0.01). Conclusion: the size of the inferior vena cava decreased and the collapse index increased significantly after dialysis in chronic kidney disease patients with hemodialysis.
Article Details
Keywords
Inferior vena cava, chronic kidney disease, hemodialysis.
References


2. Rudski L. G., Lai W. W., Afilalo J., et al. (2010). Guidelines for the echocardiographic assessment of the right heart in adults: a report from the American Society of Echocardiography endorsed by the European Association of Echocardiography, a registered branch of the European Society of Cardiology, and the Canadian Society of Echocardiography. J Am Soc Echocardiogr, 23 (7), 685-713; quiz 786-688

3. Hafiz, M.A.E.H., Mohamed, E.A., Mohamed, M.A.E.N. et al. (2021). Inferior vena cava diameter and collapsibility index as a marker of fluid status in regular hemodialysis patients. Egypt J Intern Med 33, 43 https://doi.org/10.1186/ s43162- 021-00072-x.


4. Shrestha, SK, Ghimire, A., Ansari, SR, & Adhikari, A. (2018). Use of handheld ultrasound to estimate fluid status of hemodialysis patients. Nep Med J 1(2):65–69.

5. Reeves PB, Mc Causland FR (2018) Mechanisms, clinical implications, and treatment of intradialytic hypotension. Clin J Am Soc Nephrol 13(8): 1297–1303. https://doi.org/10.2215/CJN. 12141017


6. Taniguchi T, Ohtani T, Nakatani S, Hayashi K, Yamaguchi O, Komuro I (2015), et al. Impact of Body Size on Inferior Vena Cava Parameters for Estimating Right Atrial Pressure: A Need for Standardization?