ANATOMICAL CHARACTERISTICS OF THORACIC PEDICLES ON COMPUTED TOMOGRAPHY IMAGES AT VIET DUC UNIVERSITY HOSPITAL

Hoàng Long Nguyễn, Xuân Tuấn Nguyễn, Anh Tú Nguyễn

Main Article Content

Abstract

Objective: This study aims to describe in detail the anatomical characteristics of the thoracic pedicle in adult Vietnamese individuals, evaluate its applicability in proposing appropriate screw sizes for pedicle screw fixation techniques. Methods: A cross-sectional descriptive study utilizing retrospective data was conducted on 155 adult subjects, with data collected from 3620 thoracic pedicles. The measured anatomical parameters included outer pedicle width (OPW), outer pedicle height (OPH), cortical thickness (SCT, ICT, MCT, LCT), pedicle length (PL), chord length (CL), sagittal pedicle angle (SPA), and transverse pedicle angle (TPA). Results: The male-to-female ratio was 2:1, with an average age of 31,26 ± 5,96 years. OPW decreased from T1 to T4, then increased progressively to T12, males had larger OPW than females. OPH increased from T1 to T12 and was also larger in males. Inner cortical thickness was greater than outer cortical thickness, with no significant gender difference. CL varied across vertebral levels, with CL being shorter in females. SPA increased from T1 to T6 and then decreased to T12, while TPA gradually decreased from T1 to T12. Conclusion: This study provides detailed anatomical data on thoracic pedicles in adult Vietnamese individuals, highlighting significant differences from European populations and similarities with certain Asian populations. We propose that the safe pedicle screw length for the thoracic spine ranges from 25 - 30 mm for T1 to T4, 30 - 35 mm for T5 – T12; a screw diameter of 3.5 mm at T4–T5, 4.0–4.5 mm for other levels, and ≥5.0 mm for T1, T11, and T12.

Article Details

References

Kim JH, Choi GM, Chang IB, Ahn SK, Song JH, Choi HC. Pedicular and extrapedicular morphometric analysis in the korean population : computed tomographic assessment relevance to pedicle and extrapedicle screw fixation in the thoracic spine. J Korean Neurosurg Soc. 2009;46(3): 181-188. doi:10.3340/jkns.2009.46. 3.181
2. Accuracy of pedicle screw insertion with and without computer assistance: a randomised controlled clinical study in 100 consecutive patients - PubMed. Accessed April 24, 2025. https://pubmed.ncbi.nlm.nih.gov/ 10905443/
3. Rao G, Brodke DS, Rondina M, Bacchus K, Dailey AT. Inter- and intraobserver reliability of computed tomography in assessment of thoracic pedicle screw placement. Spine. 2003;28(22): 2527-2530. doi:10.1097/01.BRS.0000092341. 56793.F1
4. Zellner AA, Prangenberg C, Roos J, et al. A computed tomography-based morphometric analysis of thoracic pedicles in a European population. J Orthop Surg. 2024;19(1):668. doi:10.1186/s13018-024-05171-3
5. Kaur K, Singh R, Prasath V, Magu S, Tanwar M. Computed tomographic-based morphometric study of thoracic spine and its relevance to anaesthetic and spinal surgical procedures. J Clin Orthop Trauma. 2016;7(2):101-108. doi:10.1016/ j.jcot.2015.12.002
6. Zhuang Z, Xie Z, Ding S, et al. Evaluation of thoracic pedicle morphometry in a Chinese population using 3D reformatted CT. Clin Anat N Y N. 2012;25(4):461-467. doi:10.1002/ca.21265
7. Liau KM, Yusof MI, Abdullah MS, Abdullah S, Yusof AH. Computed tomographic morphometry of thoracic pedicles: safety margin of transpedicular screw fixation in malaysian malay population. Spine. 2006;31(16):E545-550. doi:10. 1097/01.brs.0000225978.97652.e0
8. Fisher CG, Sahajpal V, Keynan O, et al. Accuracy and safety of pedicle screw fixation in thoracic spine trauma. J Neurosurg Spine. 2006;5(6):520-526. doi:10.3171/spi.2006.5.6.520
9. Singh R, Srivastva SK, Prasath CSV, Rohilla RK, Siwach R, Magu NK. Morphometric measurements of cadaveric thoracic spine in Indian population and its clinical applications. Asian Spine J. 2011;5(1):20-34. doi:10.4184/ asj.2011.5.1.20